Higher education
Lecture halls combine DALI-2 dimming, classroom AV interlock, and KNX shading on a single 4-Series PRO3 controller; daylight sensors trim perimeter zones per ASHRAE 90.1 §9.4.1.1(g).
Hero / gradient background
Reference architectures for higher education, corporate workplace, federal courthouses, healthcare diagnostic suites, and broadcast/AV-heavy commercial venues.
Sub-industry reference designs ship with vetted Cresnet trunk lengths, DALI-2 driver lists, BACnet/IP object schedules, and Horizon Keypad engraving sets, so a university campus facilities team or AV consultant can lift the package into the contract documents and edit only the room schedule.

Industry Pillars / horizontal scroll cards
Each vertical has its own controls archetype — daylight harvesting profiles, occupancy/vacancy logic, demand-response participation, and AV interlocks vary widely between a federal courtroom and an open-plan tech campus, and the Crestron reference designs codify those differences.
Lecture halls combine DALI-2 dimming, classroom AV interlock, and KNX shading on a single 4-Series PRO3 controller; daylight sensors trim perimeter zones per ASHRAE 90.1 §9.4.1.1(g).
Open offices run vacancy-based shutoff with 20-minute timeouts, tunable-white DT8 schedules, and Horizon Keypad scenes the workplace tech standards group can edit through SmartGraphics UI.
UL 924-listed emergency lighting interfaces, FedRAMP-Moderate XiO Cloud logging, and TAA-compliant 4-Series controllers meet GSA P100 and DoD UFC 3-530-01 requirements.
Imaging suites use circadian DT8 colour tuning interlocked with the room's AV consultant scheduling, plus UL 1069 nurse-call signaling on a segregated VLAN per FGI Guidelines.
Transformation Cases / card carousel
Representative deployments — names redacted under NDA, project metrics drawn from XiO Cloud trend data and the BMS integrator's M&V reports — show how the controls platform performs once it leaves design assist and enters facility operations.
250,000 sq ft retrofit on Cresnet over fibre to 14 IDF closets; daylight + vacancy logic delivered 38% lighting kWh reduction in year one, verified by the campus commissioning agent.
Migrated 3,200 fixtures from 0-10V to DALI-2 with phased cutover; SmartGraphics UI rolled out to 18 floors with the tenant's own workplace tech standards group authoring scenes.
UL 924 emergency lighting, dual-redundant 4-Series PRO3 controllers, and FedRAMP XiO Cloud audit trail satisfied USMS and GSA P100 cybersecurity requirements without VPN.
Tunable-white DT8 in patient rooms, BACnet/IP integration with Johnson Metasys, and Horizon Keypads compatible with FGI 2018 patient/clinician dual-control requirements.
Cta / background image
Tell us the building type, the BAS platform (Niagara, Desigo, Metasys, or Tridium), and the IECC/Title 24 climate zone, and our applications engineering team will return the matching Crestron reference design — Cresnet/DALI-2 trunk schedule, BACnet object map, and Horizon Keypad engraving template — within five business days.